Application

Brackish Water

LINE-UP

Product

HR(High Rejection) Series

It is characterized by its low operating pressure and a high rate of treated water quantity and removal.
The excellent removal performance of TDS, TOC, and SiO2 allows for a wide range of applications in the production of pure water for the purpose of producing ultrapure water used in the electronics and electrical industries.

(Application range: Feed water with a TDS below 10,000ppm)

Applications

General water treatment (Industrial/commercial water, groundwater, wastewater, etc.), High-purity demand industries (electronics/semiconductors), etc.

Product Specifications & Test Conditions

Product Specifications & Test Conditions
BWHR-
8040PRO
BWHR-
8040LD
BWHR-
8040
BWHR-
4040
BWHR-
8040B
BWHR-
4040B
Active Membrane Area
ft2 (m2)
400 (37.2) 400 (37.2) 400 (37.2) 100 (9.3) 400 (37.2) 90 (8.4)
Permeate Flow
GPD (m3/day)
11,500
(43.5)
10,500
(39.7)
10,500
(39.7)
2,800
(10.6)
10,500
(39.7)
2,400
(9.1)
Typical Rejection Rate
%
99.8 99.7 99.7 99.6 99.6 99.6
Feed Spacer Thickness
mil
34-LD 34-LD 28 28 34 34
Size Diameter
in (mm)
7.9 (201) 7.9 (201) 7.9 (201) 3.9 (99.7) 7.9 (201) 3.9 (99.7)
Length
in (mm)
40 (1,016) 40 (1,016) 40 (1,016) 40 (1,016) 40 (1,016) 40 (1,016)
Test Conditions Test Pressure
psi (Mpa)
225 (1.55)
Concentration of NaCl Solution
ppm
2,000
Recovery Rate
%
15

Operating Limit & Conditions

Operating Limit & Conditions
8040 4040
Max. Operating Pressure 600psi (4.14Mpa / 42.18kgf/cm2) 600psi (4.14Mpa / 42.18kgf/cm2)
Max. Operating Temperature 45℃ (113℉) 45℃ (113℉)
Max. Feed Flow Rate 75gpm (17m3/hr) 16gpm (3.6m3/hr)
Max. Feed SDI15 5.0 5.0
Max. Pressure Drop per Element 15psi (0.1Mpa / 1.05kgf/cm2) 15psi (0.1Mpa / 1.05kgf/cm2)
Allowed pH Range for Continuous Operation 2~11 2~11
Allowed pH Range for Chemical Cleaning 1~13 1~13
Free Chlorine Tolerance < 0.1ppm < 0.1ppm

FR(Fouling Resistant) Series

A fouling-resistant product achieved through special surface treatment, reducing the adsorption of contaminants on the membrane surface and preventing microbial proliferation. It is characterized by its low initial differential pressure, high fouling resistance, and excellent durability resulting in an extended membrane lifespan.

(Application range: Feed water with a TDS below 10,000ppm)

Applications

Public sewage reuse, wastewater reuse, treatment of raw water with high microbial contamination (COD), etc.

Product Specifications & Test Conditions

Product Specifications & Test Conditions
BWFR-8040LD BWFR-8040 BWFR-4040
Active Membrane Area
ft2 (m2)
400 (37.2) 400 (37.2) 90 (8.4)
Permeate Flow
GPD (m3/day)
10,500 (39.7) 10,500 (39.7) 2,200 (8.3)
Typical Rejection Rate
%
99.6 99.5 99.5
Feed Spacer Thickness
mil
34-LD 34 34
Size Diameter
in (mm)
7.9 (201) 7.9 (201) 3.9 (99.7)
Length
in (mm)
40 (1,016) 40 (1,016) 40 (1,016)
Test Conditions Test Pressure
psi (Mpa)
225 (1.55)
Concentration of NaCl Solution
ppm
2,000
Recovery Rate
%
15

Operating Limit & Conditions

Operating Limit & Conditions
8040 4040
Max. Operating Pressure 600psi (4.14Mpa / 42.18kgf/cm2) 600psi (4.14Mpa / 42.18kgf/cm2)
Max. Operating Temperature 45℃ (113℉) 45℃ (113℉)
Max. Feed Flow Rate 75gpm (17m3/hr) 16gpm (3.6m3/hr)
Max. Feed SDI15 5.0 5.0
Max. Pressure Drop per Element 15psi (0.1Mpa / 1.05kgf/cm2) 15psi (0.1Mpa / 1.05kgf/cm2)
Allowed pH Range for Continuous Operation 2~11 2~11
Allowed pH Range for Chemical Cleaning 1~13 1~13
Free Chlorine Tolerance < 0.1ppm < 0.1ppm

LE(Low Energy) Series

Even at a low operating pressure (70% of the HR Series), it can consistently achieve a removal rate of over 99.5%. When applied to the system, it can reduce initial investment costs and maintenance expenses.

(Application range: Feed water with a TDS below 2,000ppm)

Applications

Treatment of low-TDS water (such as tap water) and 2nd-Pass RO, etc.

Product Specifications & Test Conditions

Product Specifications & Test Conditions
BWLE-8040 BWLE-4040
Active Membrane Area
ft2 (m2)
400 (37.2) 100 (9.3)
Permeate Flow
GPD (m3/day)
10,500 (39.7) 2,600 (9.8)
Typical Rejection Rate
%
99.5 99.5
Feed Spacer Thickness
mil
28 28
Size Diameter
in (mm)
7.9 (201) 3.9 (99.7)
Length
in (mm)
40 (1,016) 40 (1,016)
Test Conditions Test Pressure
psi (Mpa)
150 (1.03)
Concentration of NaCl Solution
ppm
1,500
Recovery Rate
%
15

Operating Limit & Conditions

Operating Limit & Conditions
8040 4040
Max. Operating Pressure 600psi (4.14Mpa / 42.18kgf/cm2) 600psi (4.14Mpa / 42.18kgf/cm2)
Max. Operating Temperature 45℃ (113℉) 45℃ (113℉)
Max. Feed Flow Rate 75gpm (17m3/hr) 16gpm (3.6m3/hr)
Max. Feed SDI15 5.0 5.0
Max. Pressure Drop per Element 15psi (0.1Mpa / 1.05kgf/cm2) 15psi (0.1Mpa / 1.05kgf/cm2)
Allowed pH Range for Continuous Operation 3~10 3~10
Allowed pH Range for Chemical Cleaning 2~12 2~12
Free Chlorine Tolerance < 0.1ppm < 0.1ppm

ULE(Ultra Low Energy) Series

Even at an ultra-low operating pressure (50% of the HR Series), it can consistently achieve a removal rate of over 99.2%. When applied to the system, it can reduce initial investment costs and maintenance expenses.

(Application range: Feed water with a TDS below 1,000ppm)

Applications

Drinking water facilities, etc.

Product Specifications & Test Conditions

Product Specifications & Test Conditions
BWULE-8040 BWULE-4040
Active Membrane Area
ft2 (m2)
400 (37.2) 100 (9.3)
Permeate Flow
GPD (m3/day)
12,800 (48.4) 2,600 (9.8)
Typical Rejection Rate
%
99.2 99.2
Feed Spacer Thickness
mil
28 28
Size Diameter
in (mm)
7.9 (201) 3.9 (99.7)
Length
in (mm)
40 (1,016) 40 (1,016)
Test Conditions Test Pressure
psi (Mpa)
100 (0.69)
Concentration of NaCl Solution
ppm
500
Recovery Rate
%
15

Operating Limit & Conditions

Operating Limit & Conditions
8040 4040
Max. Operating Pressure 600psi (4.14Mpa / 42.18kgf/cm2) 600psi (4.14Mpa / 42.18kgf/cm2)
Max. Operating Temperature 45℃ (113℉) 45℃ (113℉)
Max. Feed Flow Rate 75gpm (17m3/hr) 16gpm (3.6m3/hr)
Max. Feed SDI15 5.0 5.0
Max. Pressure Drop per Element 15psi (0.1Mpa / 1.05kgf/cm2) 15psi (0.1Mpa / 1.05kgf/cm2)
Allowed pH Range for Continuous Operation 3~10 3~10
Allowed pH Range for Chemical Cleaning 2~12 2~12
Free Chlorine Tolerance < 0.1ppm < 0.1ppm

TDS

    Data Download

    Close
    Inquirer Information

    *Required fields

    • view content
      Collected Information

      Email, Name, Country, Company, Job title

      Purpose of Collection

      Homepage quality analysis and improvement, Service provision.

      Retention and use period

      3 years after requesting data download.

      ※ The collected information will not be used for purposes other than the specified purpose. ※ Service can be used after agreeing to the terms and conditions. ※ This website uses cookie information for user convenience. View terms and conditions
    • view content
      Collected Information

      Email, Name, Country, Company, Job title

      Purpose of Collection

      Information and benefits related to products, webinars, exhibitions, etc.

      Retention and use period

      3 years after requesting data download.

      ※ The collected email, name, country, company, job title, and area of interest are only used for sending marketing information in accordance with our privacy policy and will not be used for any other purpose. ※ Refusal to provide personal information and to receive emails may result in the inability to receive our services.
    Inquiry AI Chatbot
    TRILITE AI AGENT,
    Inquiry TRIGENT!
    Catalog History
    Museum
    TriAngle
    (IER)
    TriAngle
    (RO)
    Inquiry
    TOP

    We refuse unauthorized email collection

    Close

    We refuse the unauthorized collection of the email addresses on this website using email collection programs or other technical devices. Please note that any violation will be subject to criminal penalties in accordance with the Act on Information and Communications Network.

    Posted on March 28, 2023

    Cookie Popup Close
    Manage Cookies

    This site uses cookies.
    By continuing to browse the site,
    you agree to the use of cookies.

    Privacy Policy Accept