Product

Strong Base Anion Exchange Resin

Key Features

TRILITE® SBA exchange resin generally comes in two types based on the functional group:
Type 1 with TMA (Trimethylamine) as the functional group and
Type 2 with DMEA (Dimethylethanolamine) as the functional group.

Type 1 or Type 2: Which should I choose?

Both Type 1 and Type 2 are strongly basic and have salt-splitting capacity, allowing them to exchange anions such as nitrate and chloride across the entire pH range, and both are widely used.
Type 2 has lower basicity than Type 1 and therefore higher regeneration efficiency, but Type 1 has lower ion leakage than Type 2. Therefore, Type 2 is the better choice when regeneration efficiency is the priority, and Type 1 when high-purity treated water is the priority.

교환기 Type1과 Type2 비교 테이블
Item Type 1 Type 2
Functional Group TMA (Trimethylamine) DMEA (Dimethylethanolamine)
Basicity Strongest Slightly weaker than Type 1
Ease of Regeneration Difficult Easier than Type 1
SiO₂ Leakage 0.1 ppm or less 0.2 ppm or less
Chemical Stability Excellent Slightly lower than Type 1
Heat Resistance · 60℃ or less (OH form)
· 80℃ or less (Cl form)
· 40℃ or less (OH form)
· 60℃ or less (Cl form)

The typical SBA exchange resin is a styrene-based gel type and a porous type with enhanced porosity can also be selected through a special production process. The chemical structure of the porous type SBA exchange resin is the same as the gel type, but it has a large number of pores on its surface and has a higher surface area than the gel type. The porous type ion exchange resin has a high porosity and surface area, allowing for effective ion exchange even in nonpolar or high-viscosity solutions. Also, the porous type resin has a better reaction rate and decolorization ability compared to the gel type, and it has a high resistance to organic pollution, swelling strength, and shrinkage strength. However, due to the higher moisture content inside, its exchange capacity may be lower than that of a gel type resin.

When selecting an SBA exchange resin, using the gel type may be more cost-effective for general water treatment or treatment of polar solutions with less severe conditions, such as low viscosity solutions, since the production process of the porous type is more complex and therefore the unit price is higher. In the case of a porous type, high performance can be expected when used for harsh processing conditions (high temperature, high pressure),
non-polar solvent treatment, and high viscosity liquid treatment.

Product

Product Table
Product Name Product Category Information TDS

FAQ

  • Q. Should I choose the gel type or porous type of Samyang's TRILITE® strong base anion exchange resins?

    For general water treatment or low-viscosity solutions, the gel type can be considered first. For non-polar or high-viscosity solutions, or harsh conditions such as high temperature and high pressure, the porous type with greater porosity and specific surface area is advantageous, and it can also be expected to perform well in terms of reaction rate, resistance to organic fouling, and durability against swelling and shrinkage. In particular, for processes using organic solvents, it is best to select the resin by considering both the solvent characteristics and the resin's resistance to organic fouling.

    • Gel type: General water treatment, polar solutions, low-viscosity solutions
    • Porous type: Non-polar solutions, high-viscosity solutions, high temperature and high pressure

  • Q. Can Samyang's TRILITE® strong base anion exchange resins remove nitrate and chloride ions?

Data Download

Close
Inquirer Information

*Required fields

  • view content
    Collected Information

    Email, Name, Country, Company, Job title

    Purpose of Collection

    Homepage quality analysis and improvement, Service provision.

    Retention and use period

    3 years after requesting data download.

    ※ The collected information will not be used for purposes other than the specified purpose. ※ Service can be used after agreeing to the terms and conditions. ※ This website uses cookie information for user convenience. View terms and conditions
  • view content
    Collected Information

    Email, Name, Country, Company, Job title

    Purpose of Collection

    Information and benefits related to products, webinars, exhibitions, etc.

    Retention and use period

    3 years after requesting data download.

    ※ The collected email, name, country, company, job title, and area of interest are only used for sending marketing information in accordance with our privacy policy and will not be used for any other purpose. ※ Refusal to provide personal information and to receive emails may result in the inability to receive our services.
Inquiry AI Chatbot
TRILITE AI AGENT,
Inquiry TRIGENT!
Catalog History
Museum
TriAngle
(IER)
TriAngle
(RO)
Inquiry
Maximize Minimize
TOP

We refuse unauthorized email collection

Close

We refuse the unauthorized collection of the email addresses on this website using email collection programs or other technical devices. Please note that any violation will be subject to criminal penalties in accordance with the Act on Information and Communications Network.

Posted on March 28, 2023

Cookie Popup Close
Manage Cookies

This site uses cookies.
By continuing to browse the site,
you agree to the use of cookies.

Privacy Policy Accept